Design Challenge Entry


This an official entry for the Microbridge Rejustor™ Design Challenge. Use the form at the bottom of the page to leave feedback, or ask a question.
Microbridge Rejustor™ Design Challenge Official Entry
 
Title:   Precision Optical Transimpedance amplifier & OPAMP compensation
Abstract:   An optical power detector is described here. The output voltage of a TIA is simply Vo/p = I x R, where I is the current input. We can compensate errors in the circuit caused by, detector dark current variation with temperature, opamp offset(s) variation with temperature. (uV/K), and resistor temperature variation (ppm/K) .

Also described here is also a good way to compensate opamp offset.
Submitted By:   scholayil
Submitted On:   9/25/2007
Total Views:   978
 

 